- Contact Person : Ms. he Jessica
- Company Name : Hangzhou Aihua Instruments Co., Ltd.
- Tel : 86-0571-85022755
- Fax : 86-0571-85022955
- Address : Zhejiang,Hangzhou,No.453 Wensan Road,Hangzhou
- Country/Region : China
- Zip : 310007
AWA6291 Real Time Analyzer
SPECIFICATIONS
No | Model | AWA6291 |
1 | Name | Real Time Signal Analyzer |
2 | Fulfils Standards | IEC 61672 class 1 and IEC 61260 class 1 |
3 | Microphone | 1/2" Prepolarized Condenser Mic. Model AWA14423 (sensitivity: 50 mV/Pa) |
4 | Preamplifier | AWA14601 |
5 | Frequency Range | 10 Hz ~ 20 kHz |
6 | Range Gain | -10 dB, 0 dB, 10 dB, 20 dB, 30 dB, 40 dB. Range Error: ≤0.1 dB. |
7 | Self-generated Noise | <18 dB(A), 23 dB(C), 28 dB(Z) |
8 | Meas. upper Range | 140 dB |
9 | Peak C Sound Level Measuring Range | 50~143 dB |
10 | Frequency Weighting. | Parallel (simultaneous) A, C, Z. Realized by digital filtering |
11 | Time Weighting | Parallel F, S, I, Peak C+, Peak C- |
12 | A/D Bits | 24 bits |
13 | Level Linearity Range | >90 dB |
14 | Sampling Frequency | 48 kHz |
15 | Display | 240×160 graphic LCD, with EL back-lit |
16 | Display Refresh | 1 Hz for value; 10 Hz for graph |
17 | Main Parameters of Integrating Measurement | Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak+, Cpeak-, LAFmax, LAFmin, LAFeqT, LASeqT, LAIeqT Note: X is A, C, Z and Y is F, S, I |
18 | Main Parameters of Airport Noise Meas | LEPN,Td,Lmax |
19 | Display Resolution | 0.1 dB |
20 | Real-time Analysis Speed | Approx. 47 times/s (It can simultaneously complete all center frequencies and A, C, Z weighting.) |
21 | Statistical analysis Function | Statistical analysis software (S6291-00101) Statistical analysis Menu: LAFp, LAFmax, LAF5, LAF10, LAF50, LAF90, LAF95, LAFmin, SD, LAeq1 s, LAeq, T, LAE, LAFeqT. 24 hours monitors menu :And Ld, Ln, Ldn |
22 | Real-time spectrum analysis | Fulfils standards: IEC 61260 Class 1 Filter type: Digital band-pass filter Measuring Parameters: Lfmi, Lfmeq,1s, Lfmeq,T, Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak, Tm Note: fm is center frequency; X is frequency weighting A, C, Z. Y is time weighting F, S, I |
23 | Real-time 1/1 OCT spectrum analysis | 1/1 OCT spectrum analysis software for noise (S6291 -00202) Filters Center Frequency: 16 Hz~16 kHz |
24 | Real-time 1/1 OCT spectrum analysis | 1/3 OCT spectrum analysis software for noise (S6291 -00303) Filters Center Frequency: 10 Hz~20 kHz |
25 | FFT analysis function | FFT analysis software for noise (S6291 -00404) Line Number: 200 lines on the displaySampling Frequency: 48 kHz, 24 kHz, 12 kHz,6 kHz, 3 kHz, 1.5 kHz.Upper Limit of Analysis Frequency: 18.75 kHz, 9375 Hz, 4687 Hz, 2344 Hz, 1172 Hz, 586 HzBandwidth of each line: 93.75 Hz, 46.875 Hz, 23.438 Hz, 11.74 Hz, 5.8594 Hz, 2.9297 HzAverage Method: index and linearityMeasuring Parameters: Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak,Tm in every line |
26 | Reverberation time measurement function
| Reverberation time measurement software (S6291-00508) 1. Function: Reverberation time, EDT measurement by integrated impulse response method. 2. Fulfils Standard: ISO 3382 3. Measuring Parameters: T20, T30, EDT 4. Measuring Range: 0.20s to 20.00 s 5. Wave record time: 10 s or 20 s 6. Bandwidth of digital filters:1/1 OCT or 1/3 OCT 7. Center Frequency Ranges: 63 Hz ~ 16 kHz for Oct, 40 Hz ~ 16 kHz for 1/3 Oct 8. Date store: Max 12288 groups reverberation time, also translate to U disc |
27 | Data Storage | 64M bits Flash, instantaneous data, 1 second integral results and integral measuring result (maximum 12288 groups). Also can be stored in Flash disk or transferred to the Flash disk through USB interface |
28 | Integral Time | Manual, 10 s, 1 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1h, 4h, 8h, 24h or 1 min~59 min |
29 | Can print analytical results in the mini-print, can also print the contents showed on LCD | |
30 | Data Recall | Recalled any data |
31 | Intelligent Delete | Burst event may be deleted scientifically |
32 | Internal Clock | Error less than 1 min/month |
33 | Output Interface | Stereo Connector AC Signal Output RS 232 interface to the mini-printer, or connected to PC USB Interface, which can transfer the measuring results to PC, or the Flash disk |
34 | Power Supply | 6×LR6 alkaline battery or rechargeable batteries, which can work for over 12 hours continuously. 9 V external power supply is also acceptable |
35 | Dimensions | 310(H) × 90(W) × 38(D),mm |
36 | Weight | 0.5 kg (include batteries) |
37 | EMC | Type X |
38 | Working Temperature | -10 ~ 50°c |
39 | Relative Humidity | 25 ~ 90% |
40 | Atmospheric Pressure | 65 kPa ~ 108 kPa |
AWA6291 Real Time Analyzer